Search the web
Sign In
New User? Sign Up
lrig-discussion · LRIG Discussion Group is for comments or questions about Laboratory Robotics, or any Laboratory Automation topic.
? Already a member? Sign in to Yahoo!

Yahoo! Groups Tips

Did you know...
Want to share photos of your group with the world? Add a group photo to Flickr.

Best of Y! Groups

   Check them out and nominate your group.

Messages

  Messages Help
Advanced
Messages 6077 - 6106 of 6106   Oldest  |  < Older  |  Newer >  |  Newest
Messages: Simplify | Expand   (Group by Topic) Author Sort by Date ^
6077
We just bought their Synergy4 and love it. It's a dual monochromator and filter based unit with 7 read outs that meets all of our needs. You can use it with ...
frauke rininsland
fraukerin
Offline Send Email
Jun 3, 2008
3:57 am
6078
Hi Kevin, I used them a lot in Australia and they are good, nothing complicated, not the top of the line but then you rarely need an expensive instrument to do...
Agnieszka Lichanska
inez_garfield
Offline Send Email
Jun 3, 2008
3:57 am
6079
We have used BioTek plate readers for several years now, and I will tell you that I am very pleased with their performance. We use the BioTek ELx800 as part...
John Bradshaw
JBradshaw@...
Send Email
Jun 3, 2008
3:58 am
6080
At our company, we have been struggling to find conditions(pump, pump speed, tubing size, nozzle diameter, etc etc) that allow non contact dispensing of 10 -...
jitro4x7
Offline Send Email
Jun 6, 2008
3:07 am
6081
... While I can't give you info on their conditions, several of our customers are using our milliGAT-LF (http://www.globalfia.com/pumps_milligat.html) pump for...
zfwarthog
Offline Send Email
Jun 10, 2008
3:30 pm
6082
Hi all- Does anyone in the group have information about vendors providing custom Class 100 or 1000 enclosures for 2 stack/4 position Cybio Cybi-well pipettors?...
matthew.smicker@...
matthewsmicker
Offline Send Email
Jun 13, 2008
12:33 am
6083
Hello, In Europe I have used Bigneat who do a good job but I don't have a US contact. Cheers, Neil ... -- -- Neil Benn Msc CEO Ziath Ltd Website -...
Neil Benn
neil.benn@...
Send Email
Jun 13, 2008
1:30 pm
6084
Hello, I'm not certain, but I think that BioSero may be the US contact. Regards, Kevin McLeaster ... custom ... footprint ... [Non-text portions of this...
Kevin D McLeaster
kmcleaster
Offline Send Email
Jun 13, 2008
9:13 pm
6085
Hey Matt & Neil - US distributor for Bigneat biosafety cabinets is BioSero: www.bioseroinc.com <http://www.bioseroinc.com/> East coast contact would be...
Tom Wright, T-US
tom.wright@...
Send Email
Jun 13, 2008
9:13 pm
6086
Matt, My company can provide such enclosures for your application.  You can view our product specific webpage for details,...
Keith Savage
keithgsavage
Offline Send Email
Jun 13, 2008
9:14 pm
6087
we have an assay where we need to aspirate sample containing 0.5 M HCl with steel tips. Is this a problem? Any comments and recommendations are highly...
Gernot J Abel
g7gja
Offline Send Email
Jun 17, 2008
4:48 am
6088
I have a need to dispense slightly viscous solvent solutions into well plates which is proving somewhat problematic. I have been using a Flexispence HT but get...
robertwohleb
Offline Send Email
Jun 17, 2008
4:48 am
6089
Acidic halides corrode steel, even stainless steel. If contamination of your sample with metal ions is not a problem, you may be able to use steel tips on the...
Szoke, Balazs
balazsszoke
Offline Send Email
Jun 17, 2008
1:33 pm
6090
Mr. Abel, I am assuming you mean Stainless Steel SS, but with Stainless?even low M HCL solution may cause a problem. 316 SS is preferable to common 302/303/304...
amerhaj@...
amer_elhage
Offline Send Email
Jun 17, 2008
1:34 pm
6091
Yes, prolonged exposure to mineral acids will rot the steel. Brief exposure is OK, for cleaning etc., but when most HPLCs where still steel based it was a big...
Ian McFarlane
cambridgecor...
Offline Send Email
Jun 17, 2008
1:34 pm
6092
even if the tips are ok, the fumes can corrode other things exp aluminium - carefully monitor your equipment ... -- Ezra S Abrams 4 Colbert Rd Newton MA 02465...
ezra s abrams
ezracolbert@...
Send Email
Jun 17, 2008
1:35 pm
6093
Hello there, I can't find any literature/published data for CV's for a serial dilution. I am using a Tecan and am of the opinion I should be getting better...
mark ollmann
mark_r_ollmann
Offline Send Email
Jun 20, 2008
1:53 pm
6094
Does anyone know of a system that adds sterile media (250ul to 3 ml per well) to a stack of 48,24 or 12 well lidded plates, and prints and applies barcode...
awautomation
Offline Send Email
Jun 24, 2008
5:15 am
6095
Hello Everyone, Multistep pipetting processes can get ugly fast. Let us assume a best case scenario of 1% per pipetting operation. If your serial dilution...
Douglas & Colleen Gur...
dgurevitch
Offline Send Email
Jun 24, 2008
6:14 pm
6096
Hello, has anybody ever used the Matrix Visionmate 96 plus to read bottom 2D barcodes of 24-well racks/plates? I have been told by our local distributor that...
Xavier Perrodon
xavier.perrodon
Offline Send Email
Jun 24, 2008
6:14 pm
6097
Hi Xavier: It is possible with the newer version of the VisionMate96 Plus software. Give me a shout off-line and I can put you in touch with someone who can...
Wiley-Pouliot, Kacey
kaceywiley
Offline Send Email
Jun 25, 2008
6:51 am
6098
Hello Mark, My name is Kenny Drew and I am the Automation Sales Manager for ThermoFisher Scientific - Matrix Liquid Handling Equipment. The Matrix product...
Kenny Drew
matrix_autom...
Offline Send Email
Jun 26, 2008
4:29 pm
6099
The Laboratory Robotics Interest Group Discussion Group is for comments or questions about Laboratory Robotics and Automation. You receive messages posted to...
lrig-discussion@yahoo...
Send Email
Jul 1, 2008
7:54 am
6100
All, What are the lowest assay volumes successfully used in half area plates, either the ones by Corning or Greiner? The Corning brochure states a range of 75...
janicew3
Offline Send Email
Jul 2, 2008
10:58 pm
6101
Hi JW Not many but a 30 µl assay final volume worked in a Corning half plate for me Aj ... From: janicew3 <janicew3@...> Subject: [lrig-discussion]...
Andrew Johnston
hankjam
Offline Send Email
Jul 3, 2008
5:50 pm
6102
I have successfully used 9 ul final in Greiner. Chakk ________________________________ From: lrig-discussion@yahoogroups.com ...
Ramesha, Chakk
chakk.ramesha@...
Send Email
Jul 6, 2008
8:46 pm
6103
Hi I'm trying to find a dye that will shift absorbance values when it's temperature changes. In terms of sensitivity, ideally it would be something like...
sendittojack
Online Now Send Email
Jul 6, 2008
8:46 pm
6104
Hello, As you may or may not be aware, a discussion about Open Source Software has lead to a project startup called Open Lab Automation. The aim of the...
Neil Benn
neil.benn@...
Send Email
Jul 6, 2008
8:46 pm
6105
Dear colleagues, We have lost a valued partner and friend. John Morin passed away last week. He was a prolific contributor to LRIG, presenting at chapter ...
Andy Zaayenga
andy_zaayenga
Offline Send Email
Jul 6, 2008
8:50 pm
6106
*I googled your request and immediately found this article. Maybe someone has found a dye with an absorbance profile that shifts...but fluoresence is more...
James Batchelor
jbatchelor51
Offline Send Email
2:29 am
Messages 6077 - 6106 of 6106   Oldest  |  < Older  |  Newer >  |  Newest