3307
The Laboratory Robotics Interest Group Discussion Mail List is for comments or questions about Laboratory Robotics and Automation. You receive messages...
lrig-discussion@yahoo...
Send Email
Jan 3, 2004
6:31 am
3308
Dear All, I have a Mettler Toledo analytical balance that has been recently been calibrated and is giving me some problems. When I attempt to weigh anything,...
B M
baovmai
Offline Send Email
Jan 6, 2004
11:47 pm
3309
BM, Who HASN'T encountered this problem? Ugh! I sympathize...it can be very frustrating at times. Personally, I've never had any luck using a static gun, and...
Nygaard, John
jgnygaard
Offline Send Email
Jan 7, 2004
6:04 am
3310
is there a chance that you are weighing something that could evaporate or accumulate atmospheric water? cm ... From: B M [mailto:bvm25@...] Sent:...
Charlie Moffett
charliemoffett
Offline Send Email
Jan 7, 2004
6:05 am
3311
Don't discount the possibility of a problem with the balance, either mechanical or electronic. A service call may be in order. R. McIntosh ... From: B M...
Roger McIntosh
roger@...
Send Email
Jan 7, 2004
12:42 pm
3312
I know this may sound silly, but check under the balance pan for any junk that may have built up. Bill Haller ... From: B M [mailto:bvm25@...] Sent:...
William P Haller
billh@...
Send Email
Jan 7, 2004
1:37 pm
3313
I see this problem continually when weighing samples in microtiter plates. In July we did a study which showed that the "normal" surface charge on polystyrene...
Peter Kieselbach
petek@...
Send Email
Jan 7, 2004
10:57 pm
3314
I thought that might've been the culprit initially but then I attempted weighing empty glass vials with the same result. ... ...
B M
baovmai
Offline Send Email
Jan 7, 2004
10:57 pm
3315
BM, The symptoms you describe sound so much like static that it is hard to believe it could be anything else - especially since the Mettler service rep...
John Petracca
john@...
Send Email
Jan 7, 2004
10:57 pm
3316
I seem to recall that the Haug unit offers a flexible point ionization unit in addition to a U-shaped pass through unit (both can be used at the same time)....
Huggins, Zachary
Zachary.Huggins@...
Send Email
Jan 7, 2004
11:48 pm
3317
We have had extensive experience with Haug single point ionizers. Our Tecan automated weigh station is equipped dual balances that incorporate a single point...
Noonan, Jeffrey
jnoonan@...
Send Email
Jan 9, 2004
7:44 am
3318
Hello All, This may be a little off topic, but since most robotic screening systems use some sort of fluorescence technology, perhaps someone can help. Several...
G. S. Hudson
gshudson@...
Send Email
Jan 9, 2004
7:45 am
3319
Thank you all for your insightful suggestions. My balance seems to be giving good results now. The level of static electricity that affects the balance in...
B M
baovmai
Offline Send Email
Jan 9, 2004
6:30 pm
3320
On behalf of the Microplate Standards Development Committee (MSDC) of the Society for Biomolecular Screening, I would like to let you know that on January 8,...
marc.feiglin@...
feiglinm
Offline Send Email
Jan 11, 2004
6:42 pm
3321
Are there technologies to plate transformed E.coli on to Genetix plates using Robotic arms and pipeting channels? I especially looking for ways to spread the...
krishna57us
Offline Send Email
Jan 12, 2004
3:36 pm
3322
Scinomix has built custom automation in the past for this specific application. Please contact me if you would like more details. Regards, Russ Leeker Phone:...
Russ Leeker
scinomix2002
Offline Send Email
Jan 12, 2004
5:41 pm
3323
Dear Ram, I shall be interested to see the replies to this thread you have started. Here at Genetix we spread E.coli using sterile glass beads. We manually...
Sarah Stephens
genetixsarah
Offline Send Email
Jan 12, 2004
5:41 pm
3324
Marc, Thanks for ALL your efforts to develop this standard through the years! Hope you are doing well ... Dan ... From: <marc.feiglin@...> To:...
Dan Roark
dan.roark@...
Send Email
Jan 12, 2004
5:41 pm
3325
Hello, We are interested in evaluating robots capable of arraying 384 well plates for biochemical assays. We are more interested in reproducibility than...
bellbrook_labs
Offline Send Email
Jan 13, 2004
10:00 pm
3326
Hi everyone I wanted to get a bit of feedback from some users of the Gilson C200 Protein Crystallography preparation system (somewhat elderly now I suppose)....
Cooke, Simon
simon.cooke@...
Send Email
Jan 13, 2004
10:00 pm
3327
Dear Ram Allegro Technologies have successfully plated cells onto Genetix plates using the Equator low volume pipetting systems in relation to optimizing the ...
Devin Donnelly
devindonnelly
Offline Send Email
Jan 13, 2004
10:01 pm
3328
BioTX Automation has also developed a system to automate this type of process in the past. An example using an Epson SCARA robot is displayed on our home page....
James D. Frost III
jfrostiii
Offline Send Email
Jan 13, 2004
10:01 pm
3329
Does anybody have any ideas on precision plate locators for positioning 1536 well plates more accurately on a liquid handling xyz platform? The standard dowel...
schwonney
Offline Send Email
Jan 14, 2004
2:11 pm
3330
Can anybody offer any advise on a method that I can use to help cool a well plate while in position on a xyz platform. Can I get something off the shelf? I...
schwonney
Offline Send Email
Jan 14, 2004
2:11 pm
3331
Hello, I'm not too aware of US (I'm assuming the amount was in US dollars) prices but I doubt that you would get something that cheap. If it's any help then...
Neil Benn
neilbenn2000
Offline Send Email
Jan 14, 2004
2:44 pm
3332
Tecan makes such a device for precisely locating plates on certain racks. Please contact me offline if this is for a Tecan platform, and I'll be glad to...
joseph.allen@...
josephmallen
Offline Send Email
Jan 14, 2004
3:23 pm
3333
Hello, We've been looking at different ways to collect DNA samples (buccal or bloodstains) on paper (FTA, 3MM, etc.). For development, we've been punching...
Mark.Timken@...
Send Email
Jan 14, 2004
4:32 pm
3334
TO the group Many times we are asked what material is best for deep well plates, polypropylene or polystyrene. My question, if chemcial resistance is not a ...
questions@...
raylsri
Offline Send Email
Jan 14, 2004
4:32 pm
3335
S, If you are using a system with a movable head on a large deck, the error in the precision is most likely due to the head position, not the plate position. ...
Troy Smith
yobyort2
Offline Send Email
Jan 14, 2004
4:33 pm
3336
Gilson Inc offers a single probe instrument for less than 20K and for a little more an 8 probe instrument. If you want more information please visit our...
Reed, Kirby
kirbysreed
Offline Send Email
Jan 14, 2004
4:33 pm