3661
The Laboratory Robotics Interest Group Discussion Mail List is for comments or questions about Laboratory Robotics and Automation. You receive messages...
lrig-discussion@yahoo...
Send Email
Jun 1, 2004
9:56 am
3662
I have a orca core system which is missing the security dongle which should be connected to the printer port on the computer. Does anyone have a system which...
jfrog07
Offline Send Email
Jun 7, 2004
1:58 pm
3663
We would like to find out if anyone has temperature rampable reader that operates at 2C to > 80C and reads 24, 96 or 384 well plates and can measure any or all...
R Robot
trobot2002
Offline Send Email
Jun 7, 2004
5:12 pm
3664
When running QC tests on Tecan Genesis CV seemed to degrade at 25ul when the source volume in a tube with split septum was low The results have actually lead...
Rob.G.Hughes@...
Send Email
Jun 7, 2004
5:14 pm
3665
Hello, Another basement colleague (apologies to everyone else who doesn't get that!) : For your problem there are two factors you may need to be aware of (I'm...
Neil Benn
neil_david_b...
Offline Send Email
Jun 8, 2004
3:30 pm
3666
Hi, I am working on a project where I would like to shake samples on an automated platform. The samples will be orbitally shaken, with a pitch of 3mm+. Ideally...
sequencing_monkey@...
sequencing_m...
Offline Send Email
Jun 8, 2004
3:32 pm
3667
I installed a four position Teleshake on one of my robotic systems several monthes ago and I am very happy with its performance. It should meet your...
R Robot
trobot2002
Offline Send Email
Jun 8, 2004
4:08 pm
3668
Try http://www.hypertask.com/ Although not listed on their site, I believe they offer a four position shaker that is more cost effective than ganging...
Kevin Keras
kevin_keras
Offline Send Email
Jun 8, 2004
5:55 pm
3669
Tomtec has a shaker that meets those specifications. It is designed to work with the Quadra 3 liquid handling system, but I adapted one last year to work on a...
Troy Smith
yobyort2
Offline Send Email
Jun 8, 2004
5:55 pm
3670
Hi ..monkey.., As already mentioned by others www.hp-lab.de is a manufacturer we have also good experience with. We just have developed with them a robotic...
joerg.dreessen@...
jdreessen2
Offline Send Email
Jun 9, 2004
2:02 pm
3671
Hello, A good shaker which is programmable and works on electro magnets rather than an offset motor is made by a company in North Wales - unfortunately I can't...
Neil Benn
neil_david_b...
Offline Send Email
Jun 9, 2004
2:15 pm
3672
I need advice on integrating automated liquid handling equipment to be used in optimizing ELISA assays with DOE software. I have experience with Stat-Ease and...
tjack4132@...
tjack4132
Offline Send Email
Jun 9, 2004
2:24 pm
3673
I am looking for a way to blanket a microtiter plate with insert gas prior to sealing it. I have a Velocity 11 PlateLoc plate sealer. Any ideas about how to...
hts814
Offline Send Email
Jun 9, 2004
4:51 pm
3674
I asked this same question a number of months ago, so can send you in a few directions: 1- Big Bear Automation has a nice little automated shaker barely bigger...
John Thomas Bradshaw
JBradshaw@...
Send Email
Jun 9, 2004
4:52 pm
3675
Titertek's new Zoom liquid handler uses a valve design (rather than peristaltic design) and there seems to be no good way to "clean" the areas between the...
hts814
Offline Send Email
Jun 9, 2004
4:52 pm
3676
I think that the shaker that Neil is referring to is the DPC "Micromix 5". It is a very good shaker, you might want to check it out. Some very limited...
GRAY (James Gray)
grayj@...
Send Email
Jun 9, 2004
4:52 pm
3677
I am looking for an automated stirrer which will keep cells uniformly in suspension, but that I can pipet out of using a 96 or 384-tip automated pipetter. In...
hts814
Offline Send Email
Jun 9, 2004
4:54 pm
3678
hts814, Although not exactly what you were asking for, I may have another solution. Instead of using a shaker or a stirrer try a reservoir that was designed to...
automat8tionguy
autom8tionguy
Offline Send Email
Jun 9, 2004
5:42 pm
3679
Have you looked at JMP software by SAS? I have not used this software myself, but it has what seems to be a wonderful DOE module that can be used with any...
hts814
Offline Send Email
Jun 9, 2004
5:42 pm
3680
Take a look at http://www.vpscientific.com/Bubble_Paddle_direct_drive.htm#VP_763 The design allows for continuous stirring whilst aspirating. A 384 well ...
John Cahill
John.Cahill@...
Send Email
Jun 9, 2004
5:42 pm
3681
Hypertask makes a nice paddle model. Works with cells or beads. Controllable speed and a clear position. www.hypertask.com Steve W. Steven Fillers, Ph.D. VP...
Steve Fillers
steve.fillers@...
Send Email
Jun 9, 2004
6:46 pm
3682
Hi, I'm looking for a disposable reagent reservoir for use with a 12 -channel pipette with a snug fitting lid for extended storage of the reagent in the...
Bob Robertson
bob_robertson@...
Send Email
Jun 9, 2004
8:13 pm
3683
Have you thought about the DYNEX Technologies DSX unit with Quick Link software? Tom Hill Cutting Edge Scientific (301)596-1840 www.cedgesci.com Representing: ...
ces1tom@...
Send Email
Jun 10, 2004
12:54 pm
3684
While I imagine it wouldn't be too hard to put a fitting in the side of the PlateLoc to purge it, realize that unless you do something to purge the plate wells...
Peter Kieselbach
petek@...
Send Email
Jun 10, 2004
12:55 pm
3685
Does anyone know of an automatable microplate reader that can keep a plate heated from 4c to 80c or anywhere near that range? ... Do you Yahoo!? Friends. Fun....
R Robot
trobot2002
Offline Send Email
Jun 10, 2004
12:55 pm
3686
Hi Abgene in the uk can supply a modified Alps 300 Heat sealer which will allow you to pass an inert gas the be passed across the plate just prior to being...
Sean Scotcher
seanofkbio
Offline Send Email
Jun 10, 2004
1:44 pm
3687
Hi I believe there are 2 companies to sell heated unit 1. Data sensor Tel 01869 249800 2. Erwin Sick Tel 01727 831121 Best Regards Sean Scotcher Future...
Sean Scotcher
seanofkbio
Offline Send Email
Jun 10, 2004
1:45 pm
3688
Hello! I am the responsible product manager for Beckman Coulter's Automated Assay Optimization (AAO) in Europe. We developed AAO software to simplify the use...
ckruell@...
Send Email
Jun 10, 2004
2:13 pm
3689
Thanks for your response Christoph, I have been in touch with Beckman sales and training staff re: AAO/Stat-Ease and am pleased with the concept. I am hoping...
Tom Jackson
tjack4132
Offline Send Email
Jun 10, 2004
5:03 pm
3690
I've considered the DSX for other purposes. I am not familiar with Quick Link. Does it interface with DOE software? Thanks, Tom Thomas M. Jackson, Ph.D. ...
Tom Jackson
tjack4132
Offline Send Email
Jun 10, 2004
5:03 pm