5348
Hi everyone, I am looking for consultant who can give a small lab a day or 2 of training on a BioMek 2000 in central North Carolina. (Apparently Beckman no...
G. S. Hudson
gshudson@...
Send Email
Oct 2, 2006
8:38 pm
5349
You might try Jeff Cahlik at Acme Automation. http://www.acme-automation.com Regards, Tim ... From: "G. S. Hudson" <gshudson@...> To: "LRIG Discussion...
Tim Blankenship, R-US
timblnknshp
Online Now Send Email
Oct 3, 2006
3:49 pm
5350
Hello I am looking for vendors of 3456-well plates besides Aurora. Thank you...
tholmesmgh
Offline Send Email
Oct 3, 2006
5:43 pm
5351
Hi Everyone, Looking for some help with a Multimek 96/384 software issue. We were told by Beckman that the only software available for the Multimek 96/384 is...
derrichster2002
Offline Send Email
Oct 3, 2006
9:42 pm
5352
Rich, you may want to contact Dan Dechert at Nanoscreen (www.nanoscreen.com). These guys make tips and heads for the MultiMek (including a 1536 head) and...
Olaf Stelling
ostelling
Offline Send Email
Oct 4, 2006
12:47 am
5353
What are the instruments in the ThermoFluor market? Does anyone know if JnJ sells it under a new name? Alex -- ~~ www.lifesabirch.org [Non-text portions of...
Alex Birch
kes_birch
Offline Send Email
Oct 4, 2006
12:47 am
5354
Hi Everyone, I would like to thank everyone that offered up their wisdom on the Multimek software issue, specially the folks at Beckman who stepped up to the...
Richard Tula
derrichster2002
Offline Send Email
Oct 5, 2006
6:17 pm
5355
Hello Group, Our core routinely purifies DNA from human whole blood - from samples that are 8-10 cc in volume. Our protocol is mostly manual in nature, using...
tgi_rtp
andy_zaayenga
Offline Send Email
Oct 5, 2006
8:05 pm
5356
HI JW: I'm no expert at flow cytometry, but I do handle marketing and sales for the Renovar CFSE Flow Cytometry reagent line - which is slightly less of a...
Tom Strader
ts_8675309
Offline Send Email
Oct 6, 2006
2:09 pm
5357
Hi Gordon: I represent a few different companies here in Madison, WI. One of them, Global GeneTechs, provides full support of and training on a variety of ...
Tom Strader
ts_8675309
Offline Send Email
Oct 6, 2006
2:10 pm
5358
Bob, Tecan has collaborated with both Invitrogen and Promega to automate their large volume whole blood extraction kits directly from 10ml of blood. Both...
Marc Feiglin, T-US
feiglinm
Offline Send Email
Oct 6, 2006
2:11 pm
5359
Relative to one well on a plate, We need to move a 1" diam 2" long rod through 2-3 inches of travel in x,y,z with ~ 0.2 mm resolution. That is, I wish to be...
ezracolbert@...
Send Email
Oct 6, 2006
3:07 pm
5360
Ezra, Try Axis New England (just over in Woburn); http://www.axisne.com/ They should be able to help you out. Kevin Keras - Caliper Life Sciences (formerly...
Kevin Keras
kevin_keras
Offline Send Email
Oct 6, 2006
4:15 pm
5361
I have just recently become aware of a company called "The Forum 360" and would be interested in LRIG members thoughts on the concept. (for the record, I have...
doringm
Offline Send Email
Oct 7, 2006
12:22 am
5362
There are old Tecan liquid handlers which have very good XYZ motions available on Ebay for very little. They are controllable by a serial line. Now, these are...
John Brohan
jbrohan
Offline Send Email
Oct 7, 2006
3:43 pm
5363
Check Greiner Bio-One. At www.greinerbiooneinc.com Regards, Amer El-Hage Principal Beeston Engineering Consulting 415-314-9267 650-854-7419 (fax) ...
amerhaj@...
amer_elhage
Offline Send Email
Oct 11, 2006
10:34 pm
5364
I'm looking for information on automation that can be used to pipet 1ml volumes into tubes and automatically cap the tubes. It would be preferable to have...
mpr122669
Offline Send Email
Oct 12, 2006
5:29 pm
5365
Hi Michael: Tecan and REMP have developed a system to do just this, with an EVO liquid handler integrated with a REMP automated capper/decapper. Contact me...
Tim Blankenship, R-US
timblnknshp
Online Now Send Email
Oct 12, 2006
7:27 pm
5366
... pipet 1ml ... automation ... Zinsser Analytic offers a number of possibilities for such work, including automated capping and decapping of threaded vial...
jimschools
Offline Send Email
Oct 14, 2006
12:34 am
5367
Hi Neil, The Forensic Science Service used this technique on all their routine samples. It works fine as long as you flush the tips inside and out after...
MJCatPAA@...
Send Email
Oct 17, 2006
1:51 pm
5368
I have a rather immediate need for an enclosure for a Biomek FX used for siRNA screening. The enclosure we are seeking would contain the system from outside ...
gmiertschin@...
Send Email
Oct 17, 2006
6:58 pm
5369
High Resolution Engineering also has experience with enclosures. We have built general enclosure as well as BSL2+ enclosures. Please visit our website...
Ann Bellinger
ambell4112
Offline Send Email
Oct 17, 2006
8:09 pm
5370
Gary, NISC put an enclosure around their FX. It has both hinged and sliding doors, positive air flow through Hepa, UV lights on a timer, fluorescent lights,...
Messer, Andrew (NIH/N...
nhgriscieng
Offline Send Email
Oct 18, 2006
12:16 am
5371
Has anyone used a benchtop reagent dispenser to plate out low volumes of hexane (5uL - 10uL/well) into 96-well plates? If not hexane, how about a similar...
Michael_Shanler@...
Send Email
Oct 18, 2006
6:47 pm
5372
Hello, Are there any thoughts out there regarding the Hamilton star systems as far as their ease of use, implementation and script maintenance. Any Help is...
D W
biorobotdude
Offline Send Email
Oct 19, 2006
9:47 pm
5373
Hello Mike, n-Hexane is a nasty organic solvent with a very low surface tension; so dripping will occur in a standard open end system i.e. a nozzle. Still from...
amerhaj@...
amer_elhage
Offline Send Email
Oct 20, 2006
2:42 pm
5374
Flow Sciences, Inc. has produced many enclosure systems specific to the Biomek FX. Please contact FSI directly at 800-849-3429 for further information. ...
Peter Burke
pburke1970
Offline Send Email
Oct 23, 2006
7:50 pm
5375
Hello Everyone, We are evaluating two scheduling software packages: Overload & Polara. Our goal is to integrate readers, sealers, Tecans, centrifuges, ... Can...
Keith Volk
jamesvolk30
Offline Send Email
Oct 24, 2006
1:38 pm
5376
I purchased a custom HEPA enclosure from Airfiltronix about 1 year ago, and have only good things to say about the specification process, as well as the...
Pechter, David
pechterd
Offline Send Email
Oct 24, 2006
1:38 pm
5377
Our FX system has an Air Clean 4000 enclosure. Positive flow HEPA. We use it to maintain sterility of cell cultures during liquid tranfers. We've had no...
Kris Eckols
kriseckols
Offline Send Email
Oct 24, 2006
3:19 pm
Messages 5348 - 5377 of 6268   Oldest  |  < Older  |  Newer >  |  Newest