Search the web
Sign In
New User? Sign Up
lrig-discussion · LRIG Discussion Group is for comments or questions about Laboratory Robotics, or any Laboratory Automation topic.
? Already a member? Sign in to Yahoo!

Yahoo! Groups Tips

Did you know...
Hear how Yahoo! Groups has changed the lives of others. Take me there.

Best of Y! Groups

   Check them out and nominate your group.

Messages

  Messages Help
Advanced
Messages 5750 - 5779 of 6106   Oldest  |  < Older  |  Newer >  |  Newest
Messages: Simplify | Expand   (Group by Topic) Author Sort by Date ^
5750
The Laboratory Robotics Interest Group Discussion Group is for comments or questions about Laboratory Robotics and Automation. You receive messages posted to...
lrig-discussion@yahoo...
Send Email
Aug 1, 2007
8:00 am
5751
Hi I would be grateful if anyone would care to share their experiences of Labvantage, positive or and negative. I would quite like to hear about impressions on...
Andrew Johnston
hankjam
Offline Send Email
Aug 1, 2007
5:42 pm
5752
I run I Core DNA Sequencing Lab and I need a set up to print small 2D barcoded labels. I plan to pre-print labels for customers to add them to their sample...
helaman
utahcorelab
Offline Send Email
Aug 8, 2007
2:32 am
5753
Hello Helaman: There also some more permanent options available in the form of tubes that are pre-2D barcoded. These types of tubes will have no chance of ...
Wiley, Kacey
kaceywiley
Offline Send Email
Aug 9, 2007
7:42 am
5754
We use a Brother PTouch PT-2700 barcode printer that was fairly inexpensive and produces much better results than the 8.5x11 sheets of labels we used to use...
Dandekar, Samir
ttigsamir
Offline Send Email
Aug 9, 2007
9:28 pm
5755
Helaman, you also might try the following. http://www.divbio.com/ (-> Products, -> Thermal Transfer Tough & Cryo-Tags) http://www.zebra.com/ James P. Gray ...
GRAY (James Gray)
grayj@...
Send Email
Aug 9, 2007
9:28 pm
5756
There are many plastic ware vendors who would sell and ship you tubes, plates, etc. with pre-printed barcodes, based on the barcoding scheme you want. Ray ... ...
Raymond Hui
fastgeometry
Offline Send Email
Aug 9, 2007
9:28 pm
5757
Helaman, Three factors need be considered here and these will have a big impact on the cost: -your printing volume, -sample process/storage condition and ...
martin wang
pri_martin
Offline Send Email
Aug 10, 2007
5:44 am
5758
Hi Does anyone on this group have any experience with Wallac's Trilux scintillation counter in relation to running a bar code reader to track individual plates...
Andrew Johnston
hankjam
Offline Send Email
Aug 11, 2007
9:03 pm
5759
First question: Objective: Make simultaneous liquid transfers ranging from about 50-200 ul volume using a 96 or 48 tip format head from 96 and 384 well master...
vmorgo
Offline Send Email
Aug 11, 2007
9:03 pm
5760
Hi Morgan, Without knowing what kind of liquid you are going to transfers, I would personally choose a Hamilton STAR system with a 96 head and 8 individual...
jacobhald
Offline Send Email
Aug 13, 2007
2:50 am
5761
The Sciclone i1000 can do the variable volume transfer using the 96 channel head. Each channel is independently controlled to aspirate and/or dispense...
Jim Batchelor
jbatchelor51
Offline Send Email
Aug 14, 2007
3:30 am
5762
Hello, Here are a few tips: 1. AFAIK there is no such system to do what you wish. I guess the reason is that you would need separate syringe motors for each...
Neil Benn
neil_david_b...
Offline Send Email
Aug 14, 2007
3:31 am
5763
Hi V. Morgan, The previous response is correct in that the Hamilton STAR system can handle your process and has the ability to approach it in a variety of...
b_houchins
Online Now Send Email
Aug 14, 2007
1:37 pm
5764
To your second question: Allmost any 4 or 8 tip liquid handler such as the CyBi®-RoboSpense can do it,, as long as the spacing of the channels can be at...
Frittrang, Alexander
frittrang02
Offline Send Email
Aug 14, 2007
9:48 pm
5765
In regard to this question, there are some of us that have some pretty simple, moronic routines (such as PCR ad nauseum) that would really appreciate someone...
Mlejnek, Ron
Ron.Mlejnek@...
Send Email
Aug 15, 2007
8:04 pm
5766
Hello Ron, The WellAware Pipetting system from BioTX is under $6000. That is because it is Personal Automation and you still need to move the pipet. But the ...
Walter Schick
wschick65
Offline Send Email
Aug 16, 2007
3:42 am
5767
Ron, Viaflo offers just such a product. Please visit our temporary website to learn more about the StatPrep single channel robotic pipettor. Feel free to...
Marc Hamel
mhamel@...
Send Email
Aug 16, 2007
3:45 am
5768
... Amen, Brother. Kevin -- Kevin Olsen Instrumentation Specialist Chemistry and Biochemistry Support Staff Room 359 Richardson Hall Montclair State University...
Kevin K. Olsen
olsenkevink
Offline Send Email
Aug 16, 2007
1:51 pm
5769
Thermo Fisher Scientific offers automated liquid handling solutions that can be adapted to many processes. We offer interchangeable pipetting head options...
Williams, Kiara
kwilliams806
Offline Send Email
Aug 16, 2007
1:53 pm
5770
Hi, I am interested in what experience people have had when reformating samples from 384 to 1536. I am looking at condensing our screening deck from 384 well...
jcswaffield
Offline Send Email
Aug 16, 2007
5:01 pm
5771
Hi Jon PAA have had a lot of experience integrating the ECHO dispensers. If you would like to contact me offline I would be happy to provide you with...
David Ley
david.ley@...
Send Email
Aug 16, 2007
5:19 pm
5772
Hello, We use a Cybio Variowell for our 1536 work and it works well and requires no magic to make it hit the well - it just works. With a 384 head we deal...
Neil Benn
neil.benn@...
Send Email
Aug 17, 2007
1:57 am
5773
Walt, I already have the "robotic arm", but it gets tired of pushing the pipette plunger a zillion times. I want the "arm' to be computer controlled so I can...
Mlejnek, Ron
Ron.Mlejnek@...
Send Email
Aug 22, 2007
2:50 am
5774
SciDynamics offers a Brady Lab ID System. Portabble Label and Bar Code Printer. Quickly and easily design and print auto serialized, bar coded labels....
questions@...
raylsri
Offline Send Email
Aug 22, 2007
2:51 am
5775
Hi Geoffrey, I will add to Balazs remarks from my instrument or system perspective. The performance metrics Cross-contamination or % Carryover measurement is...
amerhaj@...
amer_elhage
Offline Send Email
Aug 23, 2007
4:30 am
5776
We're getting ready to purchase this software and would like to hear from anyone, good or bad, about the installation/integration process and/or its...
targaceptyoung
Offline Send Email
Aug 25, 2007
2:53 am
5777
Marlene, Bill and Gary: Midwest LRIG will help you get the "TKO Chapter"started by providing seed funding for initial events and advice on how to set up...
Tom
ts_8675309
Offline Send Email
Aug 25, 2007
2:53 am
5778
A correction after reading my comment. For a start of 10 mM or 10^-2 M  and to reach 10^-15 or fM, the dynamic range would be 13 and not 15 as was...
amerhaj@...
amer_elhage
Offline Send Email
Aug 25, 2007
2:53 am
5779
Hello, I've not had any experience with Mosaic (although the Titian people I've met are knowledgeable and friendly :) ). However, I have a fair amount of...
Neil Benn
neil.benn@...
Send Email
Aug 25, 2007
2:28 pm
Messages 5750 - 5779 of 6106   Oldest  |  < Older  |  Newer >  |  Newest